Opened 10 years ago
Closed 10 years ago
#908 closed incident (fixed)
HybridWBRotary geen internet bij Disgenoten
Reported by: | huub | Owned by: | |
---|---|---|---|
Keywords: | kaagenbraassem | Cc: | |
Location: | Generiek |
Description
From: J Nota <jcnqwerty@…>
To: Ed Kikkert <ed@…>
Subject: Re: [WL::Gebruikers] Geen verbinding wireless leiden....
Date: Mon, 13 Apr 2015 19:29:12 +0200
helaas geen verbinding bij wireless leiden disgenoten... kunnen jullie
hier even naar kijken? Dank!
Change History (2)
comment:1 by , 10 years ago
comment:2 by , 10 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
rotary heeft geen vr2 (!), dmesg zegt:
vr2: <VIA VT6105M Rhine III 10/100BaseTX> port 0x1800-0x18ff mem 0xe0080000-0xe00800ff irq 15 at device 11.0 on pci0 vr2: Quirks: 0x2 vr2: Revision: 0x96 vr2: attaching PHYs failed device_attach: vr2 attach returned 6
maar reboot helpt:
vr2: <VIA VT6105M Rhine III 10/100BaseTX> port 0x1800-0x18ff mem 0xe0080000-0xe00800ff irq 15 at device 11.0 on pci0 vr2: Quirks: 0x2 vr2: Revision: 0x96 miibus2: <MII bus> on vr2 ukphy2: <Generic IEEE 802.3u media interface> PHY 1 on miibus2 ukphy2: none, 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto vr2: Ethernet address: 00:0d:b9:1d:30:26
werkt weer.
Note:
See TracTickets
for help on using tickets.
Klopt: nagios geeft 'down' voor 172.25.56.2 en 172.25.56.4