Opened 10 years ago

Closed 10 years ago

#456 closed incident (fixed)

HybridSom2-ue0-ap3 ping critical 100% packetloss

Reported by: mbreet Owned by:
Keywords: Ap Cc:
Location: Generiek

Description

In nagios bij hosts zie ik deze melding (hard) voor hybridsom2

Details suggeren dat host down is (cq deze ap)

Change History (1)

comment:1 by huub, 10 years ago

Resolution: fixed
Status: newclosed

Hier is inderdaad wat mis:
HybridSOM2# ping 172.17.2.66
PING 172.17.2.66 (172.17.2.66): 56 data bytes
ping: sendto: No buffer space available
ping: sendto: No buffer space available
...
Powercycle op de usb-poort:
HybridSOM2# usbconfig
ugen0.1: <OHCI root HUB AMD> at usbus0, cfg=0 md=HOST spd=FULL (12Mbps) pwr=SAVE
ugen1.1: <EHCI root HUB AMD> at usbus1, cfg=0 md=HOST spd=HIGH (480Mbps) pwr=SAVE
ugen1.2: <product 0x772b vendor 0x0b95> at usbus1, cfg=0 md=HOST spd=HIGH (480Mbps) pwr=ON
HybridSOM2# usbconfig -u 1 -a 2 power_off
HybridSOM2# usbconfig
ugen0.1: <OHCI root HUB AMD> at usbus0, cfg=0 md=HOST spd=FULL (12Mbps) pwr=SAVE
ugen1.1: <EHCI root HUB AMD> at usbus1, cfg=0 md=HOST spd=HIGH (480Mbps) pwr=SAVE
ugen1.2: <product 0x772b vendor 0x0b95> at usbus1, cfg=255 md=HOST spd=HIGH (480Mbps) pwr=OFF
HybridSOM2# usbconfig -u 1 -a 2 power_on
HybridSOM2# usbconfig
ugen0.1: <OHCI root HUB AMD> at usbus0, cfg=0 md=HOST spd=FULL (12Mbps) pwr=SAVE
ugen1.1: <EHCI root HUB AMD> at usbus1, cfg=0 md=HOST spd=HIGH (480Mbps) pwr=SAVE
ugen1.2: <product 0x772b vendor 0x0b95> at usbus1, cfg=0 md=HOST spd=HIGH (480Mbps) pwr=ON

en hij doet het weer:
HybridSOM2# ping 172.17.2.66
PING 172.17.2.66 (172.17.2.66): 56 data bytes
64 bytes from 172.17.2.66: icmp_seq=4 ttl=64 time=2.386 ms
64 bytes from 172.17.2.66: icmp_seq=5 ttl=64 time=2.252 ms
Ook het speeltje van onze Belgische vrienden is weer te pingen:
HybridSOM2# ping 172.17.2.67
PING 172.17.2.67 (172.17.2.67): 56 data bytes
64 bytes from 172.17.2.67: icmp_seq=0 ttl=64 time=6.687 ms

Note: See TracTickets for help on using tickets.