Index: nodes/CNodeRabo/wleiden.conf
===================================================================
--- nodes/CNodeRabo/wleiden.conf	(revision 3582)
+++ nodes/CNodeRabo/wleiden.conf	(revision 3623)
@@ -6,5 +6,5 @@
 
 $location='Dag Rabobank gebouw schipholweg';
-$master_ip='172.19.136.1';  
+$master_ip='172.19.136.1';
 $gw_open='closed';
 $nodetype='CNode';
@@ -20,8 +20,4 @@
 $LOKATIE='Schipholweg';
 
-$N='';
-$E='';
-
-
 $config{'ep0'}=sprintf <<ED0;  # Ethernet
 TYPE=ethernet
@@ -36,5 +32,4 @@
 
 
-
 OSPF_BROADCAST=no
 OSPF_NEIGHBORS=no
@@ -42,31 +37,31 @@
 ED0
 
-$config{'wi0'}=sprintf <<EW0;  # link naar CeTIM
+$config{'wi0'}=sprintf <<EW0;  # AP omni
 TYPE=wireless
-IP=172.16.0.98/30
-DESC=Link naar CeTIM
-SDESC=2cetim
+IP=$master_ip/26
+
+DESC=omni voor de buurt
+SDESC=omni
 SPEED=11534336
-POINT_TO_POINT=172.16.0.97
+
+DHCP=10-60
 
 OSPF_BROADCAST=no
-OSPF_NEIGHBORS=172.16.0.97
+OSPF_NEIGHBORS=no
 
-MODE=managed
-ESSID=il-nw.cetim3.wleiden.net
+MODE=master
+ESSID=omni.rabo.wleiden.net
+CHANNEL=11
 
-CHANNEL=1
-
-POLAR=Vert
-ANTENNA=Patch
-GAIN=15dBi
-DIRECTION=165
-BEAMWIDTH=40
-CABLE=1
+POLAR=Ver
+ANTENNA=omni
+GAIN=9dBi
+DIRECTION=omni
+BEAMWIDTH=360
+CABLE=0
 HEIGTH=22
 
-DHCP=no
+EW0
 
-EW0
 
 $config{'wi1'}=sprintf <<EW1;  # link naar Rudi
@@ -147,38 +142,38 @@
 SPEED=11534336
 POINT_TO_POINT=172.16.1.18
-                                                                                
+
 OSPF_BROADCAST=no
 OSPF_NEIGHBORS=172.16.1.18
-                                                                                
+
 DHCP=no
 EW20
-                                                                                
 
 
-$config{'wi3'}=sprintf <<EW3;  # AP omni
+$config{'wi3'}=sprintf <<EW3;  # link naar CeTIM
 TYPE=wireless
-IP=$master_ip/26
-
-DESC=omni voor de buurt
-SDESC=omni
+IP=172.16.0.98/30
+DESC=Link naar CeTIM
+SDESC=2cetim
 SPEED=11534336
-
-DHCP=10-60
-#DHCP_STATIC= host ipaq1{hardware ethernet 00:02:2D:0E:4F:0D; fixed-address 172.18.8.2;} host ipaq2{hardware ethernet 00:02:2D:09:21:28; fixed-address 172.18.8.3;}
+POINT_TO_POINT=172.16.0.97
 
 OSPF_BROADCAST=no
-OSPF_NEIGHBORS=no
+OSPF_NEIGHBORS=172.16.0.97
 
-MODE=master
-ESSID=omni.rabo.wleiden.net
-CHANNEL=11
+MODE=managed
+ESSID=il-nw.cetim3.wleiden.net
 
-POLAR=Ver
-ANTENNA=omni
-GAIN=9dBi
-DIRECTION=omni
-BEAMWIDTH=360
-CABLE=0
+CHANNEL=1
+
+POLAR=Vert
+ANTENNA=Patch
+GAIN=15dBi
+DIRECTION=165
+BEAMWIDTH=40
+CABLE=1
 HEIGTH=22
 
+DHCP=no
+
 EW3
+